Heat pumps

API Endpoints to send and retrieve the heat pump data.

Examples:

>>> client = KebaKeEnergyAPI(
>>>     host="ap4400.local",
>>>     username="test",
>>>     password="test",
>>>     ssl=True,
>>>     skip_ssl_verification=True
>>> )
>>> client.heat_pump.get_name()

get_name(position=1) async

Get the heat pump name.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
string

Heat pum tank name

get_state(position=1, *, human_readable=True) async

Get the heat pump state.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
integer or string

(0) STANDBY / (1) FLOW / (2) AUTO_HEAT / (3) DEFROST / (4) AUTO_COOL / (5) INFLOW / (6) PUMP_DOWN / (7) SHUTDOWN / (8) ERROR

get_substate(position=1, *, human_readable=True) async

Get the heat pump substate.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
integer or string

(0) NONE /(1) OIL_PREHEATING / (2, 3) PUMP_PRE_RUN / (4) RANDOM_DELAY / (5, 21, 22) PRESSURE_EQUALIZATION (6) DEFROST_PRE_FLOW / (7) DEFROST_MONITORING / (8) SNOW_DETECTION / (9) FLUSHING / (10) DEFROST_INITIALIZATION / (11) PREHEAT_FLOW / (12) DEFROST / (13, 25) DRIP / (14) DEFROST_END / (15, 16) OPEN / (17) COMPRESSOR_POST_RUN / (18) PUMP_POST_RUN / (19) LUBRICATION_PULSE / (20, 26) / REDUCED_SPEED / (23) COMPRESSOR_DELAY / (24) DEFROST_VENTING / (27) SWITCH_HEATING_COOLING / (28, 33) / WAIT_FOR_COMPRESSOR / (29) COMPRESSOR_STOP / (30) BIVALENT_LOCK / (31) LOCKED / (32) RETURN_FLOW_OFF / (34) MIXER_OPEN / (35) ZONE_VALVE / (36) ELECTRIC_DEFROST / (37) COUNTERFLOW_VALVE

get_operating_mode(position=1, *, human_readable=True) async

Get the operating mode from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
integer or string

(0) OFF / (1) ON / (2) BACKUP

set_operating_mode(mode, position=1) async

Set the operating mode from the heat pump.

Attention! Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.

PARAMETER DESCRIPTION
mode

Set the mode as integer or string (human-readable) e.g. 0 or OFF

TYPE: int | str

position

The number of the heat pumps

TYPE: int DEFAULT: 1

get_compressor_use_night_speed(position=1, *, human_readable=True) async

Get the compressor use night speed state.

PARAMETER DESCRIPTION
position

The number of the hot water tanks

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
integer or string

(0) OFF / (1) ON

set_compressor_use_night_speed(mode, position=1) async

Set the compressor use night speed.

Attention! Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.

PARAMETER DESCRIPTION
mode

Set the mode as integer or string (human-readable) e.g. 0 or OFF

TYPE: int | str

position

The number of the heat pumps

TYPE: int DEFAULT: 1

get_compressor_night_speed(position=1, *, human_readable=True) async

Get the compressor night speed.

PARAMETER DESCRIPTION
position

The number of the hot water tanks

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
float

Compressor night speed in percent

set_compressor_night_speed(speed, position=1) async

Set the compressor night speed.

Attention! Writing values should remain within normal limits, as is the case with typical use of the Web HMI. Permanent and very frequent writing of values reduces the lifetime of the built-in flash memory.

PARAMETER DESCRIPTION
speed

Set the speed in percent

TYPE: float

position

The number of the heat pumps

TYPE: int DEFAULT: 1

get_min_compressor_night_speed(position=1) async

Get the minimum compressor night speed.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Minimum compressor night speed in percent

get_max_compressor_night_speed(position=1) async

Get the maximum compressor night speed.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Maximum compressor night speed in percent

get_circulation_pump_speed(position=1) async

Get the circulation pump speed.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Circulation pump speed in percent

get_source_pump_speed(position=1) async

Get the source pump speed.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Source pump speed in percent

get_flow_temperature(position=1) async

Get the flow temperature from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Temperature in °C

get_return_flow_temperature(position=1) async

Get the return flow temperature from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Temperature in °C

get_source_input_temperature(position=1) async

Get the source input temperature from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Temperature in °C

get_source_output_temperature(position=1) async

Get the source output temperature from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Temperature in °C

get_compressor_input_temperature(position=1) async

Get the compressor input temperature from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Temperature in °C

get_compressor_output_temperature(position=1) async

Get the compressor output temperature from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Temperature in °C

get_compressor_speed(position=1) async

Get the compressor speed from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Compressor speed in percent

get_condenser_temperature(position=1) async

Get the condenser temperature from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Temperature in °C

get_vaporizer_temperature(position=1) async

Get the vaporizer temperature from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Temperature in °C

get_target_overheating(position=1) async

Get the target overheating from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Temperature in °C

get_current_overheating(position=1) async

Get the current overheating from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Temperature in °C

get_expansion_valve_position(position=1) async

Get the expansion valve position from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
int

Step position

get_high_pressure(position=1) async

Get the high pressure from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

High pressure in bar

get_low_pressure(position=1) async

Get the low pressure from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Low pressure in bar

get_heat_request(position=1, *, human_readable=True) async

Get the heat request state from the heat pump.

PARAMETER DESCRIPTION
position

The number of the external heat pumps

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
integer or string

0 (OFF) / 1 (ON)

get_compressor_power(position=1) async

Get the compressor power from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Compressor power in W

get_heating_power(position=1) async

Get the heating power from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Heating power in W

get_hot_water_power(position=1) async

Get the hot water power from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

hot water power in W

get_cop(position=1) async

Get the COP from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

COP

get_heating_energy(position=1) async

Get the heating energy from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Heating energy in kWh

get_heating_energy_consumption(position=1) async

Get the energy consumption for heating from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Energy consumption for heating in kWh

get_heating_spf(position=1) async

Get the heating SPF from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Heating SPF

get_cooling_energy(position=1) async

Get the cooling energy from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Cooling energy in kWh

get_cooling_energy_consumption(position=1) async

Get the cooling energy consumption from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Cooling energy consumption in kWh

get_cooling_spf(position=1) async

Get the cooling SPF from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Cooling SPF

get_hot_water_energy(position=1) async

Get the hot water energy from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Hot water energy in kWh

get_hot_water_energy_consumption(position=1) async

Get the hot water energy consumption from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Hot water energy consumption in kWh.

get_hot_water_spf(position=1) async

Get the hot water SPF from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Hot water SPF

get_total_thermal_energy(position=1) async

Get the total thermal energy from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Total thermal energy in kWh

get_total_energy_consumption(position=1) async

Get the total energy consumption from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

Total energy consumption in kWh

get_total_spf(position=1) async

Get the SPF from the heat pump.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
float

SPF

has_passive_cooling(position=1, *, human_readable=True) async

Check if passive cooling for the heat pump is available.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
integer or string

0 (OFF) / 1 (ON)

get_operating_time(position=1) async

Get the operating time from the external heat pump.

PARAMETER DESCRIPTION
position

The number of the external heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
integer

Operating time in seconds

get_max_runtime(position=1) async

Get the maximum runtime from the external heat pump.

PARAMETER DESCRIPTION
position

The number of the external heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
integer

Maximum runtime in seconds

get_activation_counter(position=1) async

Get the activation counter from the heat pump.

PARAMETER DESCRIPTION
position

The number of the external heat pumps

TYPE: int DEFAULT: 1

RETURNS DESCRIPTION
integer

Number of external heat source activation

has_compressor_failure(position=1, *, human_readable=True) async

Check if the heat pump has a compressor failure.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
integer or string

0 (OFF) / 1 (ON)

has_source_failure(position=1, *, human_readable=True) async

Check if the heat pump has a source failure.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
integer or string

0 (OFF) / 1 (ON)

has_source_actuator_failure(position=1, *, human_readable=True) async

Check if the heat pump has a source actuator failure.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
integer or string

0 (OFF) / 1 (ON)

has_three_phase_failure(position=1, *, human_readable=True) async

Check if the heat pump has a three-phase failure.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
integer or string

0 (OFF) / 1 (ON)

has_source_pressure_failure(position=1, *, human_readable=True) async

Check if the heat pump has a source pressure failure.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
integer or string

0 (OFF) / 1 (ON)

has_vfd_failure(position=1, *, human_readable=True) async

Check if the heat pump has a source pressure variable frequency drive (VFD) failure.

PARAMETER DESCRIPTION
position

The number of the heat pumps

TYPE: int DEFAULT: 1

human_readable

Return a human-readable string

TYPE: bool DEFAULT: True

RETURNS DESCRIPTION
integer or string

0 (OFF) / 1 (ON)